The concrete was already cut and the sanitary line exposed when we arrived. The before photo shows it clearly: an older black ABS pipe sitting in an open floor trench, with no backwater valve in place.
A lot of homes in Ottawa West are in this situation. No protection if the municipal sewer surcharges. No alarm. No automatic shutoff.
We installed a mainline backwater valve directly into the sanitary line at the floor opening. The valve sits inside an access box with a clear lid, wrapped in a yellow sleeve that keeps the housing clean and accessible for future inspections. The clear lid allows a visual check without any digging.
We also installed a backwater valve alarm. If the flap activates due to reverse flow, the homeowner receives an alert right away.
The valve itself works on a simple principle. When sewage flows in the correct direction, the flap stays open. If flow reverses, the flap closes automatically, blocking backflow. Once normal flow resumes, it opens again on its own.
It is a reliable, low-maintenance piece of equipment. Many Ottawa West homes were built before backwater valves were standard, so retrofitting one is a practical upgrade.
To find out whether your sanitary line is set up for a backwater valve, give us a call at 613-686-1971.